- Mar 12, 2018
-
-
jftt_wangshanshan authored
-
- Mar 08, 2018
- Mar 07, 2018
-
-
Wu Jing authored
-
- Mar 06, 2018
-
-
Wu Jing authored
-
- Mar 01, 2018
-
-
naoi authored
-
Wang.shanshan authored
-
naoi authored
-
naoi authored
-
- Feb 28, 2018
- Feb 27, 2018
-
-
Cedric Roux authored
The problem is the following (as reported by an user): "one UE is attached to OAI system. UE is near the antenna. Try to detach the UE and attach again. Repeat this procedure for 5-6 times. OAI system does not work and any the UE can not attach to this system. I use TEMS software and I can see MIB signaling on this UE but UE can not decode SIB1 and SIB2." What happens is that the DCI for SIB1 and SIB2 is not cleared before use. That is the bits in the 'padding' field keep the values that were set before. If the structure has been used to transmit other DCIs (eg. for UEs) in the past, it may be reused with some of those bits set to 1. When receiving this DCI, the UE won't accept it because it gets some bits at 1 where it expects them to be 0. The short-term/quick solution is to clear the 'padding' field. A better solution would be to rewrite this part of the code, which is way too complicated for what it does. But this takes too much time. In dci.h the field 'dummy' of some structures was renamed to 'padding'. The fields 'padding32' and 'padding64' were also renamed to 'padding' for consistency. Some structures (DCI2B_1_5MHz_TDD, DCI2B_10MHz_FDD, DCI2D_1_5MHz_FDD, DCI2D_5MHz_FDD, DCI2D_10MHz_FDD) had a 'padding' field at the end, which was renamed to 'padding0'. I don't know if this field should be here at all. To me this field looks very suspicious. When we test DCIs 2B and 2D we should be careful. (cherry picked from commit c5ca2bd8)
-
jftt_wangshanshan authored
-
- Feb 26, 2018
-
-
Xu Bo authored
-
Wang.shanshan authored
-
jftt_wangshanshan authored
-
- Feb 24, 2018
-
-
jftt_wangshanshan authored
-
Wu Jing authored
-
- Feb 22, 2018
-
-
Masayuki HARADA authored
-
tomita authored
-
tomita authored
-
- Feb 21, 2018
-
-
-
Masayuki HARADA authored
-
naoi authored
eNB should be keep UE context longer than T311 timer after UL failure is detected in layer2. Configuration file(GENERIC-LTE-EPC) sets T311 to 10s, so eNB keep UE context up to 20s.
-
- Feb 20, 2018
-
-
tomita authored
-
- Feb 19, 2018
- Feb 15, 2018
-
-
Masayuki HARADA authored
-
Masayuki HARADA authored
If TB buffer's all regments recieved is NOT equal RLC's all regments recieved, discard that TB buffer.
-
naoi authored
-
- Feb 14, 2018
-
-
Masayuki HARADA authored
-
- Feb 13, 2018
-
-
naoi authored
-
jftt_wangshanshan authored
Merge branch 'sp3_tdd_config1' of http://takoyaki.np1s.css.fujitsu.com:8000/gitlab/vran/release_enb into sp3_tdd_config1
-
jftt_wangshanshan authored
-
naoi authored
-
Wu Jing authored
-
- Feb 12, 2018
-
-
Wu Jing authored
-